Building on Dairyland’s proven history of industry-leading product lines, the PCRX represents the next technological leap forward in decoupling technology.

Using sophisticated design techniques that represent the work of numerous leading experts around the world, the PCRX’s active capacitance compensation renders it virtually invisible to interrupted survey testing.

Like our other decouplers, the PCRX is a solid-state, maintenance-free device designed to simultaneously provide DC decoupling and AC continuity/grounding when used with cathodically protected structures. Commonly used to decouple electric equipment from grounding systems, for AC mitigation projects, or other isolation and grounding applications, the PCRX is the most sophisticated decoupler in the world.

  • Sophisticated product design addresses interrupted survey response time
  • Robust, adaptive system senses multiple conditions
  • Addresses rectifier cycling, AC induction, and over-voltage conditions

Built with proven Dairyland technology
High product ratings for assured performance
Solid-state, maintenance-free operation

Customizable product ratings
Sturdy stainless-steel, tamper-proof enclosure
Third-party certified around the world

Client Testimonials

“Dairyland extensively tested various conditions on pipeline systems and eliminated the CIS issue”

“Dairyland’s new product reacts quickly with no perceived error in the pipe to soil readings”

“The PCRX provides a clean waveform while maintaining the required safety characteristics”

Find the perfect solution

Compare Products

  • PCRX

    AC Fault Current (AMPERES-RMS) 50/60Hz
    5.0kA at 30 cycles | 10kA at 30 cycles | 15kA at 30 cycles
    AC STEADY-STATE CURRENT
    45A
    ENVIRONMENTAL RATING
    NEMA 4X (standard) | Ambient Temperature Range: | -40C to +50C (-40 to +122F) | IP66
    Threshold Voltage
    -4.5/+3.5 | -5.5/+2.5
    LIGHTNING SURGE CURRENT
    100kA crest (8 x 20 µs waveform)
    HAZARDOUS (CLASSIFIED) AREAS
    ANSI/ISA: Class I, Division 2, Groups A, B, C, D | ATEX: Zone 2, Group IIC | IECEx: Zone 2, Group IIC | UKEx: Zone 2, Group IIC
    Current Product
  • PCRH

    AC Fault Current (Amperes-RMS) 50/60Hz
    3.7kA at 30 cycles | 5.0kA at 30 cycles | 10kA at 30 cycles | 15kA at 30 cycles
    AC Steady-State Current
    45A (standard)
    Environmental Rating
    NEMA 4X, IP66
    Threshold Voltage
    -3/+1V (standard) | -2/+2V (optional)
    Lightning Surge Current
    100kA crest (8 x 20 µs waveform)
    Hazardous (Classified) Areas
    ANSI/ISA: Class I, Division 1 & 2, Groups B, C, D | ATEX: Zone 1 Group IIB | IECEx: Zone 1 Group IIB | EAC: Zone 1, Group IIB | UKEx: Zone 1, Group IIB
  • PCR

    AC Fault Current (Amperes-RMS) 50/60Hz
    3.7kA at 30 cycles | 5.0kA at 30 cycles | 10kA at 30 cycles | 15kA at 30 cycles
    AC Steady-State Current
    45A (standard) | 80A (optional)
    Environmental Rating
    NEMA 4X (standard) | NEMA 6P (optional)
    Threshold Voltage
    -3/+1V (standard) | -2/+2V (optional) | -4/+1V (optional)* | -6/+1V (optional)*
    Lightning Impulse Current
    100kA crest (8 x 20 µs waveform)
    Hazardous (Classified) Areas
    ANSI/ISA: Class I, Division 2, Groups A, B, C, D | ATEX: Zone 2, Group IIC | IECEx: Zone 2, Group IIC | UKEx: Zone 2, Group IIC
  • SSD

    AC Fault Current (Amperes-RMS) 50/60Hz
    1.2kA at 30 cycles | 2.0kA at 30 cycles | 3.7kA at 30 cycles | 5.0kA at 30 cycles
    AC Steady-State Current
    45A (standard) | (amperes - rms) 50/60Hz
    Environmental Rating
    IP68 - submersible (to 2m depth — enclosure only)
    Threshold Voltage
    -2/+2V (standard) | -3/+1V (optional)
    Lightning Impulse Current
    100kA crest (8 x 20 µs waveform) (standard) | Class N 50kA crest* (10 x 350 µs waveform) | *optional unless required by international standards
    Hazardous (Classified) Areas
    ANSI/ISA: Class I, Division 2, Groups A, B, C, D | ATEX: Zone 2, Group IIC | IECEx: Zone 2, Group IIC | EAC: Zone 2, Group IIC | UKEx: Zone 2, Group IIC

PCRX Model Numbers

Technical Specs

AC Fault Current (AMPERES-RMS) 50/60Hz
5.0kA at 30 cycles
10kA at 30 cycles
15kA at 30 cycles

Review the Technical Literature for full fault current tables.

AC STEADY-STATE CURRENT
45A
ENVIRONMENTAL RATING
NEMA 4X (standard)
Ambient Temperature Range:
-40C to +50C (-40 to +122F)
IP66
Threshold Voltage
-4.5/+3.5
-5.5/+2.5
LIGHTNING SURGE CURRENT
100kA crest (8 x 20 µs waveform)
HAZARDOUS (CLASSIFIED) AREAS
ANSI/ISA: Class I, Division 2, Groups A, B, C, D
ATEX: Zone 2, Group IIC
IECEx: Zone 2, Group IIC
UKEx: Zone 2, Group IIC

Certifications

Certifications

The PCRX has been tested by Nationally Recognized Testing Laboratories (NRTLs) for compliance to independent standards in its operation, ratings, and construction. This includes compliance to standards for:

Class I, Div. 2, Groups A, B, C, D and Zone 2, Group IIC.

Class & Division System: UL (United States) and C-UL (Canada)

  • Effective Ground Fault Current Path per:
    • NFPA 70 (US National Electric Code – NEC): Article 250.4(A)(5)
    • CSA C22.1 (Canadian Electric Code, Part I): 10-100 & 10-500
  • Isolation of Objectionable DC Ground Currents per:
    • NFPA 70: Article 250.6(E) CSA C22.1: 10-100 & 10-500
  • Hazardous Location Use: Class 1, Division 2, Groups A, B,C,D by UL & C-UL per:
    • UL 121201, 9th Ed. and CSA C22.2 No.213-17
  • Safety Requirements for Electrical Equipment per:
    • UL 61010-1, 3rd Ed. & CSA C22.2 No. 61010-1
    • Overvoltage Protection from Impulse (Lightning) Current: 100kA (8 x 20µs)
    • Enclosure Rating: NEMA 4X • Temperature Range: -40°C to +50°C (-40°F to +122°F)
    • Max Altitude: 2000 meters
    • Ambient Pressure of 80 kPa (0.8 bar) to 110 kPa (1.1 bar)
    • Relative Humidity: 0-100% noncondensing
    • Outdoor use
    • Pollution Degree 2

Zone System: ATEX / IECEx / UKEx (Europe / International / UK). ATEX per directive 2014/34/EU (Equipment for use in Potentially Explosive Atmospheres):

  • Zone 2, Group IIC, Increased Safety “ec”
  • EN IEC 60079-0: 2018
  • EN IEC 60079-7: 2015+A1:2018
  • IEC 60079-0: 2017
  • IEC 60079-7: 2017
  • Overvoltage Protection from Impulse (Lightning) Current: 100kA (8 x 20µs)
  • Temperature Range: -40°C to +50°C
  • Enclosure Rating: IP66